點(diǎn):就是套筒式測(cè)管的接頭或者是管口或者是管底發(fā)生密封不嚴(yán)的情況,那么在施工的過程中它就會(huì)發(fā)生漏漿造成堵塞的情況,這時(shí)候要檢查密封情況,看不是工人在焊接過程中有漏焊的情況,找到漏焊點(diǎn)進(jìn)行補(bǔ)焊就可以了。
The first point: if the joint or nozzle or bottom of the sleeve type measuring pipe is not tightly sealed, it will be blocked by slurry leakage during construction. At this time, check the sealing to see if there is missing welding during welding, and find the missing welding point for repair welding.
第二點(diǎn)是它在安裝時(shí)接頭發(fā)生錯(cuò)位或者是變形,這時(shí)候大家就需要知道這是因?yàn)檫x用的材料過薄引起的,這種情況就要和廠家協(xié)商調(diào)換厚壁聲測(cè)管,套筒式聲測(cè)管建議用1.8mm以上的。
The second point is that the joint is misaligned or deformed during installation. At this time, we need to know that this is caused by the selected material is too thin. In this case, we need to negotiate with the manufacturer to replace the thick wall acoustic pipe. It is recommended to use a sleeve acoustic pipe of more than 1.8mm.